Gebruik de reader hieronder om de Structural Concepts Oasis B424TM Koelkast handleiding te lezen. U kunt de handleidingen direct op de pagina doorbladeren en de functies van onze reader gebruiken om alle belangrijke informatie over de installatie, bediening en het onderhoud van deze Structural Concepts Koelkast te vinden.
Handleiding
Volledig schermProbleemoplossing
Praktische tips om de meest voorkomende problemen met Structural Concepts Oasis B424TM op te lossen.
Oorzaak: Drain trap contains debris, drain hose incorrectly positioned, or hot gas condensate pan not properly connected
Check that the drain trap is free of debris. Check that the drain hose is correctly positioned over evaporator pan. Check that the hot gas condensate pan is properly connected and heating. Check store conditions (Type 1: max 55% humidity/75°F, Type 2: max 60% humidity/80°F). Wicking material may be dirty or worn and need replacement.
Oorzaak: Case misalignment, dirty evaporator fan, motor bearing wear, loose mounting, or fan shroud not properly secured
Check that the case is aligned, level and plumb. Check evaporator fan for cleanliness. Unplug/power off fan motor and check motor shaft for bearing wear. Check that fan motor is securely mounted in bracket. Verify that fan blades are securely mounted to fan motor. Check that nothing is preventing blade rotation. Check that the fan shroud is properly secured.
Oorzaak: Light switch off, light cords/plugs not properly connected, or circuit breaker tripped
Check that light switch is in the on position. Check that ALL of the light cords and plugs are properly connected. Check circuit breaker box for tripped circuit. If case lights still do not come on, call service provider.
Oorzaak: Light cords or plugs not properly connected, oval form of plug not matching oval form of LED light
Check that ALL of the light cords and plugs are properly connected. Ensure oval form of plug connects to oval form of LED light. See LED LIGHT FIXTURE section for specifics. If case light still does not come on, call service provider.
Oorzaak: Warm product added without pre-chilling, case in sun or near heat source, location near front doors causing temperature fluctuation, filter/condenser coil dirty, air grilles obstructed, or low refrigerant charge
Pre-chill product before placing in case. Check that the case is not in the sun or near a heat or air-conditioning vent. If located near front doors, temperature fluctuation may hinder temperature maintenance. Check that filter and condenser coil has been cleaned. Check air return grilles for obstructions. Do not set product on air grilles. Check sight glass for flashing and/or low charge. Check Set Point Temperature setting.
Oorzaak: MAIN power switch off, fan motor not plugged in, foreign material obstruction, or power not reaching fan
Check that the MAIN power switch is on. Check that fan motor is plugged in at the fan shroud. Check for foreign material obstructing fan performance. Check that fan blades freely rotate within fan shroud. Check that power is going to fan. Check that fan wiring is connected on terminal blocks.
Oorzaak: MAIN power switch off or circuit breaker tripped
Check that the MAIN power switch is on. Check the circuit breaker box for tripped circuits.
Oorzaak: Utility power off, MAIN power switch off, or circuit breaker tripped
Check that the utility power is on. Check that the MAIN power switch is on. Check the circuit breaker box for tripped circuits.
Oorzaak: Defrost cycle in progress or temperature control settings not properly configured
See your case's thermostat label near temperature controller for your model's required settings. Fourth LED on temperature controller will indicate defrost cycle in progress. Temperature changes during defrost mode but will return to normal.
Oorzaak: Condensing coil dirty, condensing fans not working, refrigerant overcharged, contaminates in system, liquid line filter dryer plugged, close-offs not intact, or store ambient temperature too high
Check that the condensing coil is not dirty or covered. Check that condensing fans are working. Check that refrigerant is not overcharged. Perform sub-cooling check and verify that no contaminates are in system. Check that liquid line filter dryer is not plugged. Check that close-offs are intact around condensing coil and that air is not recirculating. Check that store ambient temperature is not above maximum allowed.
Oorzaak: Low refrigerant charge or bad compressor reed valves
Check if sight glass is flashing or showing low charge. Check that suction pressure is not too low. Check that compressor reed valves are not bad. Look for high suction/low head pressure. Perform pump down.
Oorzaak: Low refrigerant charge, restricted expansion valve, restricted liquid line or filter, kinked refrigeration lines, evaporator fan not working, iced up evaporator coil, or air recirculation
Check if sight glass is flashing or showing low charge. Check that expansion valve (TXV) is not restricted and check element charge. Check that liquid line or filter is not restricted. Check that refrigeration lines and/or hoses are not kinked on either high or low sides. Check that evaporator fan motors are working. Check superheat. Check that there is no air recirculation around evaporator coil. Check that evaporator coil is not iced up.
Oorzaak: Refrigerant overcharge, bad compressor reed valves, high cooling load, case near doors or HVAC vents, direct sunlight exposure, superheat adjustment too low, or TXV bulb installation issues
Check for refrigerant overcharge. Check that compressor reed valves are not bad. Check that the cooling load is not high. Product must be pre-chilled before placing in refrigerated section. Check that case is at least 15-feet from exterior doors, overhead HVAC vents or any air curtain disruption. Check that unit is not exposed to direct sunlight or other heat sources. Check that superheat adjustment is not too low. Check TXV bulb installation for poor thermal contact or warm location.
Veelgestelde Vragen
De meest gestelde vragen over de Structural Concepts Oasis B424TM.
Hulp
Heb je vragen over de Koelkast Oasis B424TM van Structural Concepts? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.
Gerelateerde handleidingen
Hieronder vindt u handleidingen voor Koelkast die vergelijkbaar zijn met Oasis B424TM. Probeer ook alle Structural Concepts Koelkast handleidingen te bekijken
Discussie
Laat een opmerking achter of stel een vraag
Doe mee aan de discussie
Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.