Gebruik de reader hieronder om de Structural Concepts Oasis B424TM Koelkast handleiding te lezen. U kunt de handleidingen direct op de pagina doorbladeren en de functies van onze reader gebruiken om alle belangrijke informatie over de installatie, bediening en het onderhoud van deze Structural Concepts Koelkast te vinden.

Handleiding

Volledig scherm
Volledig scherm
Deel deze handleiding Structural Concepts
Was deze handleiding nuttig?

Probleemoplossing

Praktische tips om de meest voorkomende problemen met Structural Concepts Oasis B424TM op te lossen.

Water Is On The Floor water

Oorzaak: Drain trap contains debris, drain hose incorrectly positioned, or hot gas condensate pan not properly connected

Oplossing

Check that the drain trap is free of debris. Check that the drain hose is correctly positioned over evaporator pan. Check that the hot gas condensate pan is properly connected and heating. Check store conditions (Type 1: max 55% humidity/75°F, Type 2: max 60% humidity/80°F). Wicking material may be dirty or worn and need replacement.

Fan Emits Excessive Noise noise

Oorzaak: Case misalignment, dirty evaporator fan, motor bearing wear, loose mounting, or fan shroud not properly secured

Oplossing

Check that the case is aligned, level and plumb. Check evaporator fan for cleanliness. Unplug/power off fan motor and check motor shaft for bearing wear. Check that fan motor is securely mounted in bracket. Verify that fan blades are securely mounted to fan motor. Check that nothing is preventing blade rotation. Check that the fan shroud is properly secured.

No Case Lights Are Working power

Oorzaak: Light switch off, light cords/plugs not properly connected, or circuit breaker tripped

Oplossing

Check that light switch is in the on position. Check that ALL of the light cords and plugs are properly connected. Check circuit breaker box for tripped circuit. If case lights still do not come on, call service provider.

Case Light Is Not Working power

Oorzaak: Light cords or plugs not properly connected, oval form of plug not matching oval form of LED light

Oplossing

Check that ALL of the light cords and plugs are properly connected. Ensure oval form of plug connects to oval form of LED light. See LED LIGHT FIXTURE section for specifics. If case light still does not come on, call service provider.

Case is Not Holding Proper Temperature temperature

Oorzaak: Warm product added without pre-chilling, case in sun or near heat source, location near front doors causing temperature fluctuation, filter/condenser coil dirty, air grilles obstructed, or low refrigerant charge

Oplossing

Pre-chill product before placing in case. Check that the case is not in the sun or near a heat or air-conditioning vent. If located near front doors, temperature fluctuation may hinder temperature maintenance. Check that filter and condenser coil has been cleaned. Check air return grilles for obstructions. Do not set product on air grilles. Check sight glass for flashing and/or low charge. Check Set Point Temperature setting.

Fan Is Not Working performance

Oorzaak: MAIN power switch off, fan motor not plugged in, foreign material obstruction, or power not reaching fan

Oplossing

Check that the MAIN power switch is on. Check that fan motor is plugged in at the fan shroud. Check for foreign material obstructing fan performance. Check that fan blades freely rotate within fan shroud. Check that power is going to fan. Check that fan wiring is connected on terminal blocks.

Digital Control Display Is Blank power

Oorzaak: MAIN power switch off or circuit breaker tripped

Oplossing

Check that the MAIN power switch is on. Check the circuit breaker box for tripped circuits.

System Not Operating power

Oorzaak: Utility power off, MAIN power switch off, or circuit breaker tripped

Oplossing

Check that the utility power is on. Check that the MAIN power switch is on. Check the circuit breaker box for tripped circuits.

Control Display Is Flashing temperature

Oorzaak: Defrost cycle in progress or temperature control settings not properly configured

Oplossing

See your case's thermostat label near temperature controller for your model's required settings. Fourth LED on temperature controller will indicate defrost cycle in progress. Temperature changes during defrost mode but will return to normal.

Head Pressure Too High temperature

Oorzaak: Condensing coil dirty, condensing fans not working, refrigerant overcharged, contaminates in system, liquid line filter dryer plugged, close-offs not intact, or store ambient temperature too high

Oplossing

Check that the condensing coil is not dirty or covered. Check that condensing fans are working. Check that refrigerant is not overcharged. Perform sub-cooling check and verify that no contaminates are in system. Check that liquid line filter dryer is not plugged. Check that close-offs are intact around condensing coil and that air is not recirculating. Check that store ambient temperature is not above maximum allowed.

Head Pressure Too Low compressor

Oorzaak: Low refrigerant charge or bad compressor reed valves

Oplossing

Check if sight glass is flashing or showing low charge. Check that suction pressure is not too low. Check that compressor reed valves are not bad. Look for high suction/low head pressure. Perform pump down.

Low Suction Pressure temperature

Oorzaak: Low refrigerant charge, restricted expansion valve, restricted liquid line or filter, kinked refrigeration lines, evaporator fan not working, iced up evaporator coil, or air recirculation

Oplossing

Check if sight glass is flashing or showing low charge. Check that expansion valve (TXV) is not restricted and check element charge. Check that liquid line or filter is not restricted. Check that refrigeration lines and/or hoses are not kinked on either high or low sides. Check that evaporator fan motors are working. Check superheat. Check that there is no air recirculation around evaporator coil. Check that evaporator coil is not iced up.

High Suction Pressure temperature

Oorzaak: Refrigerant overcharge, bad compressor reed valves, high cooling load, case near doors or HVAC vents, direct sunlight exposure, superheat adjustment too low, or TXV bulb installation issues

Oplossing

Check for refrigerant overcharge. Check that compressor reed valves are not bad. Check that the cooling load is not high. Product must be pre-chilled before placing in refrigerated section. Check that case is at least 15-feet from exterior doors, overhead HVAC vents or any air curtain disruption. Check that unit is not exposed to direct sunlight or other heat sources. Check that superheat adjustment is not too low. Check TXV bulb installation for poor thermal contact or warm location.

Veelgestelde Vragen

De meest gestelde vragen over de Structural Concepts Oasis B424TM.

Preventief onderhoud moet elk kwartaal door getrainde servicemedewerkers worden uitgevoerd. Dit omvat reiniging van de condenseringsspoel, het koelsysteem, het binnenste van de kast en de honingraatluchtdiffuser.

Voor Type 1-omstandigheden: maximaal 55% luchtvochtigheid en 75°F. Voor Type 2-omstandigheden: maximaal 60% luchtvochtigheid en 80°F.

Ja, product moet altijd vooraf worden afgekoeld. Als een grote hoeveelheid warm product aan de kast wordt toegevoegd, duurt het langer voordat de temperatuur zich aanpast en kan de kast de juiste temperatuur niet handhaven.

De kast mag niet in direct zonlicht staan en mag niet dicht bij verwarmingsbronnen (ovens, frituurpannen) of airconditioning-ventielen staan. De kast moet minimaal 15 meter van buitendeuren en HVAC-ventielen verwijderd zijn.

Controleer dat alle lichtkabels en stekkers correct zijn aangesloten. De ovale vorm van de stekker moet overeenkomen met de ovale vorm van de LED-lamp. Raadpleeg de sectie LED-lichtfixtures in deze handleiding voor specifieke instructies en illustraties.

Controleer of het afvoerputje vrij is van vuil. Zorg ervoor dat de afvoerslang correct over de verdamperbak is gepositioneerd. Controleer dat de warmtegascondensaatpan correct is aangesloten en verwarmd. Controleer ook of het waspapier voor het condensaatsysteem niet vuil of versleten is.

Verwijder de achtergrille door deze op te tillen en eraf te halen. Gebruik luchtdruk of een industriële stofzuiger om stof en vuil van de condenseringsspoel te verwijderen. Let op: spoelvinnen zijn scherp. Zorg voorzichtig om. Vervang de achtergrille.

Een knipperende temperatuurregelaar kan aangeven dat een ontdooist cyclus bezig is. Controleer de thermostatlabel in uw kast. De vierde LED op de temperatuurregelaar geeft aan dat de ontdooicyclus actief is. De temperatuur zal terugkeren naar normaal na het ontdooien.

Hulp

Heb je vragen over de Koelkast Oasis B424TM van Structural Concepts? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Koelkast die vergelijkbaar zijn met Oasis B424TM. Probeer ook alle Structural Concepts Koelkast handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in