Foutcodes

Hieronder vindt u de error codes voor de Tosot GPC08AO-A3NNA1A.

E8 power
WAARSCHUWING

Overload malfunction

Oplossing

1. Check if the unit is under a high-temperature and high-humidity environment; restart the unit after the ambient temperature drops to 95°F (35°C) below. 2. Check if the evaporator and condenser are blocked. If the malfunction codes still occur, please contact the manufacturer for help.

F0 other
KRITIEK

Refrigerant leakage

Oplossing

Please contact the manufacturer for help.

F1 sensor
KRITIEK

Ambient temperature sensor malfunction

Oplossing

Please contact the manufacturer for help.

F2 sensor
KRITIEK

Evaporator temperature sensor malfunction

Oplossing

Please contact the manufacturer for help.

F4 sensor
KRITIEK

Exhaust hose temperature sensor malfunction

Oplossing

Please contact the manufacturer for help.

H3 power
WAARSCHUWING

Overload malfunction

Oplossing

1. Check if the unit is under a high-temperature and high-humidity environment; restart the unit after the ambient temperature drops to 95°F (35°C) below. 2. Check if the evaporator and condenser are blocked. If the malfunction codes still occur, please contact the manufacturer for help.

H8 water
WAARSCHUWING

Chassis is full of water

Oplossing

Please refer to the 'Removing Collected Water' part on page 19. If 'H8' still exists, please contact the manufacturer.

Probleemoplossing

Praktische tips om de meest voorkomende problemen met Tosot GPC08AO-A3NNA1A op te lossen.

Air conditioner can't operate performance

Oorzaak: 3-Minute Compressor Protection is active

Oplossing

Wait for 3 minutes, then turn on the unit again.

Air conditioner can't operate power

Oorzaak: Plug is loose

Oplossing

Reinsert the plug.

Air conditioner can't operate power

Oorzaak: Power failure

Oplossing

Wait after power recovery.

Air conditioner can't operate power

Oorzaak: Power is too low

Oplossing

Wait after voltage is resumed.

Air conditioner can't operate power

Oorzaak: Unit is interfered seriously (static pressure, unstable voltage)

Oplossing

Pull out the plug. Insert the plug after about 3 minutes, then turn on the unit.

Poor cooling maintenance

Oorzaak: Air filter is too dirty

Oplossing

Clean the air filter.

Poor cooling temperature

Oorzaak: Set temperature is not proper

Oplossing

Adjust the temperature.

Poor cooling performance

Oorzaak: Door and window are not closed

Oplossing

Close door and window.

Air conditioner can't receive signals from remote control or remote control is not sensible connectivity

Oorzaak: Remote control is not within the receiving range

Oplossing

The receiving range of remote control is 25 feet. Do not exceed this range.

Air conditioner can't receive signals from remote control or remote control is not sensible connectivity

Oorzaak: Obstacles are blocking the remote control signal

Oplossing

Remove the obstacles.

Air conditioner can't receive signals from remote control or remote control is not sensible connectivity

Oorzaak: Sensitivity of remote control is low

Oplossing

Check the batteries of the remote control. If the power is low, please replace the batteries.

Air conditioner can't receive signals from remote control or remote control is not sensible connectivity

Oorzaak: Fluorescence lamp in the room is interfering

Oplossing

Move the remote control close to the air conditioner.

Set temperature cannot be adjusted temperature

Oorzaak: The unit is in auto mode

Oplossing

Exit auto mode to adjust temperature.

Set temperature cannot be adjusted temperature

Oorzaak: Desired temperature exceeds the AC range

Oplossing

Set temperature range is 61-86°F.

Air blowing from the air conditioner has a weird smell maintenance

Oorzaak: Source of odor is somewhere in the room

Oplossing

Remove the source of the odor and clean the filter.

Abnormal sound during operation (flowing water sound) noise

Oorzaak: Unit has just been turned on or off

Oplossing

This is the refrigerant inside the air conditioner, which is completely normal.

Abnormal sound during operation (rapid pop-pop sound) noise

Oorzaak: Unit has just been turned on or off

Oplossing

Changing temperature can cause the panel to shrink or expand, causing friction. This is normal.

Veelgestelde Vragen

De meest gestelde vragen over de Tosot GPC08AO-A3NNA1A.

Alle TOSOT airconditioners hebben een 3-Minute Compressor Protection-functie om de levensduur van uw apparaat te verlengen. Dit gebeurt wanneer de compressor moet beschermd worden, bijvoorbeeld na een stroomuitval, bij het overschakelen van ventilator- of droogmodus naar koelmodus, bij herhaalde inschakeling binnen 3 minuten, of wanneer de omgevingstemperatuur lager is dan de ingestelde temperatuur.

Controleer of het luchtfilter schoon is en maak het indien nodig schoon. Zorg ervoor dat de ingestelde temperatuur juist is en dat deuren en ramen gesloten zijn. Wacht ook na het inschakelen op de 3-minuten compressorbeveiliging.

Het ontvangstbereik van de afstandsbediening is 25 voet (ongeveer 7,6 meter). Zorg ervoor dat u niet verder weg bent dan dit bereik en dat er geen obstakels tussen de afstandsbediening en het apparaat zijn.

Foutcode H8 geeft aan dat het chassis vol water zit. Raadpleeg de instructies onder 'Verwijdering van verzameld water' op pagina 19. Als H8 nog steeds aanwezig is, neem contact op met de fabrikant.

Controleer eerst of de afstandsbediening binnen het bereik van 25 voet is. Verwijder vervolgens alle obstakels. Controleer de batterijen in de afstandsbediening en vervang deze indien de spanning laag is. Als er fluorescente buizen in de kamer zijn, brengt u de afstandsbediening dichter bij het apparaat.

Raadpleeg de sectie 'Verwijdering van verzameld water' op pagina 19 van deze handleiding voor gedetailleerde instructies. Als het probleem aanhoudt, neem dan contact op met de fabrikant.

Het temperatuurinstelbereik is 61-86°F (ongeveer 16-30°C). In automodus kunnen sommige temperaturen niet worden aangepast.

Ja, het is volledig normaal. Het stromende water is het koudemiddel in de airconditioner. Dit treedt op als het apparaat net is ingeschakeld of uitgeschakeld.

De TOSOT Portable Air Conditioner wordt geleverd met een 1-jarige garantie vanaf de aankoopdatum, met dekking voor fabricage- en materiaalfouten. U kunt een extra 6-maanden garantieverlenging krijgen door uw product in te schrijven op www.tosotdirect.com/extend.

Abnormale geluiden kunnen veroorzaakt worden door waterstroming (normaal) of expansie/contractie van het paneel (normaal bij temperatuurveranderingen). Als het geluid echter aanhoudend en abnormaal is, schakel het apparaat uit en neem contact op met de fabrikant.

Hulp

Heb je vragen over de Airco GPC08AO-A3NNA1A van Tosot? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Airco die vergelijkbaar zijn met GPC08AO-A3NNA1A. Probeer ook alle Tosot Airco handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in