Gebruik de reader hieronder om de Delfield CoolScapes GBSF1P-S Vriezer handleiding te lezen. U kunt de handleidingen direct op de pagina doorbladeren en de functies van onze reader gebruiken om alle belangrijke informatie over de installatie, bediening en het onderhoud van deze Delfield Vriezer te vinden.
Handleiding
Volledig schermFoutcodes
Hieronder vindt u de error codes voor de Delfield CoolScapes GBSF1P-S.
Box temperature sensor circuit is either open or shorted
Check resistance of sensor for open or short and replace sensor if either condition is found. If not, replace control.
Communication error between controller and display
Check for loose plugs on cable from control to display. If there are no loose plugs the display or control may need to be replaced.
Coil temperature sensor circuit is either open or shorted
Check resistance of sensor for open or short and replace sensor if either condition is found. If not, replace control.
Control has a defective potentiometer
Replace control.
Probleemoplossing
Praktische tips om de meest voorkomende problemen met Delfield CoolScapes GBSF1P-S op te lossen.
Oorzaak: Fuse blown or circuit breaker tripped
Replace fuse or reset circuit breaker.
Oorzaak: Power cord unplugged
Plug in power cord.
Oorzaak: Thermostat set too high
Set thermostat to lower temperature.
Oorzaak: Main power switch turned off
Turn main power switch on.
Oorzaak: Cabinet in defrost cycle
Wait for defrost cycle to finish.
Oorzaak: Excessive amount of warm product placed in cabinet
Allow adequate time for product to cool down.
Oorzaak: Prolonged door openings or door(s) ajar
Make sure door(s) are closed when not in use. Avoid prolonged door openings.
Oorzaak: Door gasket(s) not sealing properly
Check gasket condition. Adjust door or replace gasket if necessary.
Oorzaak: Dirty condenser coil
Clean the condenser coil.
Oorzaak: Evaporator coil iced over
Turn unit off and allow coil to defrost. Make sure thermostat is not set too cold. Also, check gasket condition.
Oorzaak: Thermostat set too high
Set thermostat to lower temperature.
Oorzaak: Poor air circulation in cabinet
Re-arrange product to allow proper air circulation.
Oorzaak: Exterior thermometer is out of calibration
Re-calibrate thermometer.
Oorzaak: Excessive amount of warm product placed in cabinet
Allow adequate time for product to cool down.
Oorzaak: Prolonged door openings or door(s) ajar
Make sure door(s) are closed when not in use. Avoid prolonged door openings.
Oorzaak: Dirty condenser coil
Clean the condenser coil.
Oorzaak: Evaporator coil iced over
Turn unit off and allow coil to defrost. Make sure thermostat is not set too cold. Also, check gasket condition.
Oorzaak: Loose part(s)
Locate and tighten loose part(s).
Oorzaak: Thermostat is set too low
Set thermostat to higher temperature.
Oorzaak: Dirty condenser coil
Clean the condenser coil.
Oorzaak: Not enough cabinet clearance for proper refrigeration system operation
Move cabinet or make other adjustments to gain proper cabinet clearances.
Oorzaak: Low voltage to cabinet
Check and correct incoming voltage to cabinet.
Hulp
Heb je vragen over de Vriezer CoolScapes GBSF1P-S van Delfield? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.
Gerelateerde handleidingen
Hieronder vindt u handleidingen voor Vriezer die vergelijkbaar zijn met CoolScapes GBSF1P-S. Probeer ook alle Delfield Vriezer handleidingen te bekijken
Discussie
Laat een opmerking achter of stel een vraag
Doe mee aan de discussie
Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.