Gebruik de reader hieronder om de Honeywell SMHOM9510KIT Thermostaat handleiding te lezen. U kunt de handleidingen direct op de pagina doorbladeren en de functies van onze reader gebruiken om alle belangrijke informatie over de installatie, bediening en het onderhoud van deze Honeywell Thermostaat te vinden.

Handleiding

Volledig scherm
Volledig scherm
Deel deze handleiding Honeywell
Was deze handleiding nuttig?

Probleemoplossing

Praktische tips om de meest voorkomende problemen met Honeywell SMHOM9510KIT op te lossen.

Display is blank power

Oorzaak: Power issue, circuit breaker tripped, heating/cooling system switch off, furnace door open, missing C wire, or incorrect R/Rc jumper setting

Oplossing

Check circuit breaker and reset if necessary. Make sure power switch for heating & cooling system is on. Make sure furnace door is closed securely. Make sure the C wire is connected. Make sure the R/Rc jumper is set correctly (see page 15).

Heating or cooling system does not respond temperature

Oorzaak: Incorrect system mode, desired temperature not set appropriately, power issue, heating/cooling system switch off, furnace door open, or system needs time to respond

Oplossing

Press Menu > System Mode > Heat > Done to set to Heat mode and ensure desired temperature is higher than indoor temperature. Press Menu > System Mode > Cool > Done to set to Cool mode and ensure desired temperature is lower than indoor temperature. Check circuit breaker and reset if necessary. Make sure power switch for heating & cooling system is on. Make sure furnace door is closed securely. Wait 5 minutes for the system to respond.

Temperature settings do not change temperature

Oorzaak: Minimum and maximum limit settings are restricting temperature adjustments

Oplossing

Verify limit settings. Heat has a setting range of 40-90°F and cool has a range of 50-99°F.

Aux heat runs in cooling installation

Oorzaak: Wire incorrectly attached to W terminal on UWP for heat pump systems

Oplossing

For heat pump systems, verify there is not a wire attached to W on the UWP.

Cool runs with a call for heat installation

Oorzaak: Wire incorrectly attached to W terminal on UWP for heat pump systems

Oplossing

For heat pump systems, verify there is not a wire attached to W on the UWP.

Veelgestelde Vragen

De meest gestelde vragen over de Honeywell SMHOM9510KIT.

Yes, a C (common) wire is required for 24V AC power. If you do not have a C wire, a free C wire adapter offer is included.

It is compatible with most heat pump/heating and cooling systems. It does not work with portable electric baseboard heaters (120V to 240V) or millivolt systems.

Resideo warrants this product to be free from defects in workmanship or materials for a period of two (2) years from the date of first purchase by the original purchaser.

Check the circuit breaker and reset if necessary. Ensure the power switch for heating & cooling system is on, the furnace door is closed securely, the C wire is connected, and the R/Rc jumper is set correctly.

Wait 5 minutes for the system to respond after making changes.

Heat has a setting range of 40-90°F and cool has a range of 50-99°F.

Yes, the T9 Pro Smart supports Apple HomeKit. Scan the setup code on the back cover of the guide included with your T9 Smart thermostat when prompted by the Honeywell Home app.

Hulp

Heb je vragen over de Thermostaat SMHOM9510KIT van Honeywell? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Thermostaat die vergelijkbaar zijn met SMHOM9510KIT. Probeer ook alle Honeywell Thermostaat handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in