Gebruik de reader hieronder om de Honeywell RTH7500D Thermostaat handleiding te lezen. U kunt de handleidingen direct op de pagina doorbladeren en de functies van onze reader gebruiken om alle belangrijke informatie over de installatie, bediening en het onderhoud van deze Honeywell Thermostaat te vinden.

Handleiding

Volledig scherm
Volledig scherm
Deel deze handleiding Honeywell
Was deze handleiding nuttig?

Probleemoplossing

Praktische tips om de meest voorkomende problemen met Honeywell RTH7500D op te lossen.

Display is blank power

Oorzaak: Batteries not installed or depleted

Oplossing

Check that fresh AA alkaline batteries are installed as marked on the thermostat

Temperature settings do not change temperature

Oorzaak: Settings outside valid range

Oplossing

Check that the temperature settings are: Heating 40°F to 90°F (4.5°C to 32°C), Cooling 50°F to 99°F (10°C to 37°C)

Heating system does not turn on temperature

Oorzaak: Multiple possible causes including system mode, settings, power issues, or circuit breaker

Oplossing

Set the system to Heat by pressing the System button. Check the heat temperature setting is above room temperature and 'Heat On' shows solidly. Verify circuit breaker is not tripped. Check power switch at heating system is on. Check furnace door is closed securely. Wait five minutes for system to respond. If issue persists, contact local heating and cooling contractor

Cooling system does not turn on temperature

Oorzaak: Multiple possible causes including system mode, settings, power issues, or circuit breaker

Oplossing

Set the system to Cool by pressing the System button. Check the cool temperature setting is below room temperature and 'Cool On' shows solidly. Verify circuit breaker is not tripped. Check power switch at cooling system is on. Check furnace door is closed securely. Wait five minutes for system to respond. If issue persists, contact local heating and cooling contractor

Cannot set System setting to Cool installation

Oorzaak: Installer Setup Number 0170 setting does not match installed system type

Oplossing

Check Installer Setup Number 0170, Heating and/or Cooling System Type; make sure the setting matches the installed heating and/or cooling system

'Heat On' is not shown in the display temperature

Oorzaak: System mode or temperature setting incorrect

Oplossing

Set the System setting to Heat and set the temperature setting above the room temperature. If 'Heat On' is shown solidly but heating system does not turn on, see 'Heating system does not turn on' troubleshooting

'Cool On' is not shown in the display temperature

Oorzaak: System mode or temperature setting incorrect

Oplossing

Set the System setting to Cool and set the temperature setting below the room temperature. If 'Cool On' is shown solidly but cooling system does not turn on, see 'Cooling system does not turn on' troubleshooting

'Wait' shows in the display compressor

Oorzaak: Compressor minimum-off timer is active

Oplossing

Wait up to five minutes for the cooling or heating system to turn on

Fan does not turn on in a call for heat (electric furnaces only) installation

Oorzaak: Installer Setup Number 0180 setting not configured for Electric Heat

Oplossing

Check Installer Setup Number 0180, Fan Control in Heating, and make sure it is set to Electric Heat

Heat pump puts out cool air in the heat mode and warm air in the cool mode (heat pumps only) installation

Oorzaak: Installer Setup Number 0190 changeover valve setting does not match installed heat pump

Oplossing

Check Installer Setup Number 0190, Heat Pump Changeover Valve, and make sure the setting matches the changeover required by the installed heat pump

Both the heating and cooling systems are running at the same time installation

Oorzaak: System type setting mismatch or wiring issue

Oplossing

Check Installer Setup Number 0170, Heating and/or Cooling System Type, and make sure the setting matches the installed system. Check and make sure the bare portions of the wires are not touching

Heating system is running in cool mode installation

Oorzaak: Installer Setup Number 0170 setting does not match installed system type

Oplossing

Check Installer Setup Number 0170, Heating and/or Cooling System Type, and make sure the setting matches the installed heating and/or cooling system

Heating system does not turn off and the heat temperature setting is set below the room temperature ('Heat On' is not shown in display) installation

Oorzaak: Installer Setup Number 0170 setting does not match installed system type

Oplossing

Check Installer Setup Number 0170, Heating and/or Cooling System Type, and make sure the setting matches the installed heating and/or cooling system

Red LED is on in the upper left corner and the Heat Pump is not working other

Oorzaak: System monitor is wired to the thermostat L terminal

Oplossing

See 'Heating or Cooling system does not turn on' in the Troubleshooting Tips

Veelgestelde Vragen

De meest gestelde vragen over de Honeywell RTH7500D.

Voor verwarming: 40°F tot 90°F (4,5°C tot 32°C). Voor koeling: 50°F tot 99°F (10°C tot 37°C).

Gebruik verse AA alkalinebatterijen. Zorg ervoor dat ze correct zijn geplaatst zoals aangegeven op de thermostaat.

Druk op de System-knop om het systeem in te stellen op Heat (verwarming) of Cool (koeling).

Dit betekent dat de compressor-minimumtimer actief is. Wacht tot vijf minuten totdat het koel- of verwarmingssysteem inschakelt.

Het systeem kan tot vijf minuten nodig hebben om in te schakelen nadat u de instellingen hebt gewijzigd.

Controleer of de temperatuurinstelling correct is ingesteld (boven kamertemperatuur voor verwarming, onder voor koeling), of 'Heat On' of 'Cool On' op het display wordt weergegeven, of de stroomonderbreker is uitgeschakeld, of de aan/uitschakelaar van het systeem is ingeschakeld, en of de furnacedeur goed gesloten is.

Dit product (zonder batterij) heeft een beperkte garantie van één jaar tegen gebreken in verwerking of materialen onder normaal gebruik. Voor defecten kunt u het retourneren naar de winkel of naar het adres van Honeywell Return Goods.

U kunt contact opnemen met Honeywell Customer Care via 1-800-468-1502 of www.honeywell.com/yourhome voor ondersteuning.

Hulp

Heb je vragen over de Thermostaat RTH7500D van Honeywell? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Thermostaat die vergelijkbaar zijn met RTH7500D. Probeer ook alle Honeywell Thermostaat handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in