Gebruik de reader hieronder om de ATAG Energion Nuos Plus 200 Ketel & boiler handleiding te lezen. U kunt de handleidingen direct op de pagina doorbladeren en de functies van onze reader gebruiken om alle belangrijke informatie over de installatie, bediening en het onderhoud van deze ATAG Ketel & boiler te vinden.

Handleiding

Volledig scherm
Volledig scherm
Deel deze handleiding ATAG
Was deze handleiding nuttig?

Foutcodes

Hieronder vindt u de error codes voor de ATAG Energion Nuos Plus 200.

007 sensor
WAARSCHUWING

NTC Condenser: Open or Short Circuit

Oplossing

Verify NTC Condenser proper functioning

008 sensor
WAARSCHUWING

NTC Discharge (Compressor Outlet): Open or Short Circuit

Oplossing

Verify NTC Discharge proper functioning

009 sensor
WAARSCHUWING

NTC Air: Open or Short Circuit

Oplossing

Verify NTC Air proper functioning

010 sensor
WAARSCHUWING

NTC Evap: Open or Short Circuit

Oplossing

Verify NTC Evap proper functioning

012 sensor
WAARSCHUWING

NTC Suction (Compressor Inlet): Open or Short Circuit

Oplossing

Verify NTC Suction proper functioning

021 compressor
KRITIEK

Gas Leak

Oplossing

Verify compressor inlet sensor proper functioning. If error persists, recover residual gas; find leak in cooling circuit; repair it; make vacuum and recharge circuit with 1100g of refrigerant gas

032 compressor
KRITIEK

Compressor Issue

Oplossing

Check power voltage on compressor connector. Turn off the appliance

042 fan
WAARSCHUWING

Evaporator Obstructed

Oplossing

Check that the evaporator and the external unit casing is not obstructed

044 fan
WAARSCHUWING

Fan Issue

Oplossing

Check power voltage on fan connector. Control the proper functioning of sensor at compressor inlet

051 compressor
WAARSCHUWING

High Pressure

Oplossing

Check pressure switch wiring. Verify gas quantity

053 compressor
KRITIEK

Compressor Thermal Protector: KO

Oplossing

Check compressor connector

081 compressor
WAARSCHUWING

Electronic Expansion Valve Issue

Oplossing

Verify expansion valve cables. Verify NTC suction and NTC Evap correct functioning

218 sensor
WAARSCHUWING

Dome NTC sensor (hot water): Open or Short Circuit

Oplossing

Verify NTC sensor (hot water) proper functioning

230 sensor
WAARSCHUWING

Water Temperature Sensor (Heating Element Zone): Open or Short Circuit

Oplossing

Check the correct assembly of sensor wiring on related mainboard connector. Verify sensor proper functioning

231 sensor
WAARSCHUWING

Water Temperature sensor (Heating Element Zone): safety intervention (1st level)

Oplossing

Verify sensor proper functioning

232 sensor
KRITIEK

Water Temperature sensor (Heating Element Zone): safety intervention (2nd level)

Oplossing

Verify sensor proper functioning

233 power
KRITIEK

Relay blocked

Oplossing

Reset the appliance by pressing the ON/OFF button twice. If the error persists, replace the motherboard

241 other
WAARSCHUWING

Impressed Current Anode: Open Circuit

Oplossing

Check the presence of water inside the product. If the error persists, verify the anode proper functioning. Check the correct assembly of anode wiring on related mainboard connector. If the error persists, replace mainboard

314 power
INFORMATIE

ON / OFF repeated

Oplossing

Wait 15 minutes before unlocking the product with ON/OFF button

321 communication
KRITIEK

Corrupted data

Oplossing

Reset the product by pressing the ON / OFF button twice. If the error persists, replace the motherboard

331 communication
KRITIEK

Missing communication between Main Board and HMI

Oplossing

Reset the product by pushing the ON/OFF button twice. If the error persists, replace the mainboard-display communication wiring

332 communication
WAARSCHUWING

Mainboard – WiFi board missing communication

Oplossing

Check cables between motherboard and HMI. If the error persists, replace the HMI module. If WiFi not present: Enter to the Installer Menu and set P31 OFF. If the error occurs again, replace the Main Board

333 communication
WAARSCHUWING

Mainboard – WiFi board missing communication

Oplossing

Check cables between motherboard and HMI. If the error persists, replace the HMI module. If WiFi not present: Enter to the Installer Menu and set P31 OFF. If the error occurs again, replace the Main Board

334 communication
WAARSCHUWING

Missing Communication between Inverter and main board

Oplossing

Check the communication cable and the related motherboard and TDC cables. If the error persists, replace the TDC

335 communication
KRITIEK

Safety board communication failure

Oplossing

Reset the product by pressing the ON / OFF button twice. If the error persists, replace the motherboard

336 display
WAARSCHUWING

Touch screen not working

Oplossing

Reset the product by pressing the ON / OFF button twice. If the error persists, replace the HMI

337 communication
WAARSCHUWING

Cascade master missing

Oplossing

Check that at least one of the products in the cascade is set as Master, otherwise set one

Probleemoplossing

Praktische tips om de meest voorkomende problemen met ATAG Energion Nuos Plus 200 op te lossen.

Water delivered is cold or insufficiently hot temperature

Oorzaak: Temperature setting is low

Oplossing

Raise the water temperature setting

Water delivered is cold or insufficiently hot other

Oorzaak: Machine malfunctioning

Oplossing

Check for errors on the display and follow the instructions on the Errors table

Water delivered is cold or insufficiently hot power

Oorzaak: No electrical connection, wires disconnected or damaged wires and connections

Oplossing

Check the voltage on the power terminals, check the condition of the wires and connections

Water delivered is cold or insufficiently hot connectivity

Oorzaak: HC/HP signal missing (if the product is installed with EDF signal cable)

Oplossing

To check the operation of the product start the Boost mode; if the outcome is positive check the presence of the HC/HP signal from the meter and check that the EDF cabling is intact

Water delivered is cold or insufficiently hot temperature

Oorzaak: Malfunctioning of the timer for the two-tier rate (if the product is installed with this configuration)

Oplossing

Check the operation of the day/night meter and that the set time is sufficient to heat the water

Water delivered is cold or insufficiently hot maintenance

Oorzaak: Insufficient air flow to the evaporator

Oplossing

Clean the grilles and ducts regularly

Water delivered is cold or insufficiently hot power

Oorzaak: Product is switched OFF

Oplossing

Check the mains power supply. Switch the product ON

Water delivered is cold or insufficiently hot temperature

Oorzaak: Use of a significant amount of hot water when the product is in heating phase

Oplossing

Wait for the heating phase to complete

Water is boiling (with possible steam on the taps) temperature

Oorzaak: Sensor error

Oplossing

Check for NTC errors, even occasional ones

Water is boiling (with possible steam on the taps) maintenance

Oorzaak: High level of limescale build-up in the boiler and components

Oplossing

Unplug the power supply, empty the appliance, remove the heating element sheath and clean the limescale from the inside of the boiler, taking care not to damage the enamel on the boiler and the heating element sheath. Reassemble the product in its original configuration. Replace the flange gasket

Reduced operation of the heat pump, electrical heating element is in almost continuous operation temperature

Oorzaak: Sensor error

Oplossing

Check for NTC errors, even occasional ones

Reduced operation of the heat pump, electrical heating element is in almost continuous operation temperature

Oorzaak: Time W value too low

Oplossing

Set a lower temperature parameter or a higher Time W parameter

Reduced operation of the heat pump, electrical heating element is in almost continuous operation power

Oorzaak: Installation performed with non-compliant electricity power supply (voltage too low)

Oplossing

Power the product with the correct voltage

Reduced operation of the heat pump, electrical heating element is in almost continuous operation maintenance

Oorzaak: Evaporator obstructed or frozen

Oplossing

Make sure that the evaporator is clean

Reduced operation of the heat pump, electrical heating element is in almost continuous operation other

Oorzaak: Problems with the heat pump circuit

Oplossing

Check the display for error messages

Reduced operation of the heat pump, electrical heating element is in almost continuous operation performance

Oorzaak: 8 days have not passed yet since initial start-up, Time W parameter change, or power failure

Oplossing

Wait 8 days

Insufficient hot water flow water

Oorzaak: Leaks or obstructions in the hydraulic circuit

Oplossing

Check the circuit for leaks, check the condition of the deflector on the inlet cold water pipe and the integrity of the delivery hot water pipe

Water leaking from the pressure safety device during the heating phase water

Oorzaak: It is normal for some water to drip from the device on the delivery system

Oplossing

If the leak continues even after the heating phase, check the calibration of the device and the mains water pressure. To prevent water from dripping, an expansion vessel must be installed. Never obstruct the device's discharge outlet

Increased noise level noise

Oorzaak: Presence of an internal obstruction

Oplossing

Check the moving components of the unit, clean the fan and other moving parts which could cause noise

Increased noise level noise

Oorzaak: Some components are vibrating

Oplossing

Check the components connected using mobile clamps, ensuring the screws are well tightened

Problems with viewing the display or the display turning off connectivity

Oorzaak: Failure or electrical connection problems between the motherboard and the interface PCB

Oplossing

Check the connection status and the correct operation of the PCBs

Problems with viewing the display or the display turning off power

Oorzaak: Power failure

Oplossing

Check the power supply

A bad odour is coming from the product maintenance

Oorzaak: No siphon or siphon is empty

Oplossing

Install a siphon. Ensure it contains the necessary amount of water

A bad odour is coming from the product other

Oorzaak: Leaks or partial obstruction in the refrigerant gas circuit

Oplossing

Switch the product ON in heat pump mode, use a leak detector for the specific circuit

Veelgestelde Vragen

De meest gestelde vragen over de ATAG Energion Nuos Plus 200.

Het apparaat wordt geproduceerd met de volgende standaardwaarden: werkingsmodus GROEN, standaardtemperatuur 55°C, maximale temperatuur met verwarmingselement 75°C, minimale temperatuur 40°C, maximale temperatuur met warmtepomp 62°C, antibacteriële bescherming UITGESCHAKELD, vakantiestand UITGESCHAKELD, ontdooiing INGESCHAKELD, HC-HP tweelagentarief UITGESCHAKELD, hysterese 12°C.

Als een storing optreedt, schakelt het apparaat naar storingsmodus en toont het display knippersignalen met een foutcode. De warmwaterboiler levert nog steeds warm water als de storing slechts één van de twee verwarmingseenheden betreft, door de warmtepomp of het verwarmingselement in te schakelen.

Het wordt aanbevolen het evaporatorfilter minstens eenmaal per jaar schoon te maken om stof en obstakels te verwijderen. Na onderhoud moet het apparaat met water gevuld en volledig gedraineerd worden. Controleer regelmatig of de condensafvoerleiding niet verstopt is en zorg voor een ongehinderde afvoer.

Verbreek permanent de stroomtoevoer, sluit de afsluiter of centrale tap af, open de warmwaterkraan, en open de kraan op het drukbeveiligingsapparaat of de speciale kraan op de T-fitting zoals beschreven in de hydraulische aansluiting.

Het is normaal dat er enig water uit het apparaat druppelt op het aflevering- systeem. Als het lek doorgaat na de verwarmingsfase, controleer de kalibratie van het apparaat en de netwatersdruk. Een expansievat moet worden geïnstalleerd om waterdruppels te voorkomen.

Het filter kan met de juiste clip boven de behuizingen worden uitgehaald. Reinig het filter met water en mild zeep. Controleer of de buitenuitgang van de luchtafvoergang en de gang zelf niet verstopt zijn of niet zijn beschadigd.

Controleer op NTC-fouten, ook incidentele. Zorg ervoor dat alle sensorbedrading correct op de moederbord-connectoren is aangesloten. Als het probleem aanhoudt, moet de sensor of moederbord worden vervangen.

De maximale temperatuur die u kunt instellen met het verwarmingselement is 75°C. Met de warmtepomp is de maximale instelbare temperatuur 62°C.

U moet 8 dagen wachten na het eerste starten, een wijziging van de Time W-parameter, of na een stroombijzaak voordat het apparaat volledig operationeel is.

Hulp

Heb je vragen over de Ketel & boiler Energion Nuos Plus 200 van ATAG? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Ketel & boiler die vergelijkbaar zijn met Energion Nuos Plus 200. Probeer ook alle ATAG Ketel & boiler handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in