1.1 Regulation
5
1.2 Warnings
5
1.3 Manual Handling
5
1.4 Warnings On The Box
5
1.5 Pictograms
5
This Manual
6
1.6 Product Identification
7
2.1 General
8
2.2 The Installation
8
2.3 Approvals
9
3.1 Technical Data
10
3.2 Product Fiche According To Celex-32013R0811, Annex Iv
11
4.1 General Boiler Information
13
4.8 Operation
14
4.9 Operating Modes
14
4.10 Clock Function
16
4.11 Pc Interface
16
4.12 Test Programs
17
4.12.1 Frost Protection
17
5.1 Accessories
19
5.2 Flues
19
6.1 Overall Dimensions
20
6.2 Boiler Location
21
6.2.1 Installation In A Kitchen Cupboard
21
6.2.2 Installation In An Airing Cupboard
21
6.2.3 Remove Front Panel
21
6.3 Assembly
22
6.3.1 Fitting The Mounting Strip
22
6.3.2 Fitting The Spacer Frame
22
6.4 Mount The Appliance
23
7.1 Connect The Ch System
24
7.1.1 Expansion Vessel
25
7.1.2 Thermostatic Radiator Valves
25
7.1.3 Underfloor Heating
25
Appliance With Zone Control
26
7.2 Domestic Hot Water System
27
7.2.1 Appliance With Solar Water Heater Post-Heating
27
7.3 Electrical Connection
28
7.3.1 Electrical Connections
28
7.3.2 On / Off Room Thermostat
29
7.3.3 Open Therm Room Thermostat
29
7.3.4 Outside Temperature Sensor
29
7.3.5 230 Volt Room Thermostat
29
7.3.6 S And Y Zone Plans
29
7.4 Condensate Disposal
30
7.5 Gas Connection
31
7.6 Flue System
32
7.6.1 General
32
7.6.2 Sealed Flue System
32
7.6.3 Flue Pipe And Air Supply
33
7.6.5 Horizontal Flue System
34
7.6.6 Vertical Flue System
34
7.6.7 Plume Management Kit
35
7.6.8 Flues In Voids
35
7.6.9 Free In The Market Availabe Flue Systems (C63)
37
7.6.10 Dimensions Flue Gas Materials:
37
7.6.11 Securing The Flue System
38
8.1.1 Fill And De-Aerate The Appliance And The System
40
8.1.1 Ch System
40
8.1.2 Hot Water Supply
40
8.1.3 Gas Supply
40
8.1.4 Flue System
41
8.2 Commissioning Of The Appliance
42
8.3 Setting And Adjusting The Clock Functions
43
8.3.1 Setting The Clock
43
8.3.2 Setting The Timer Function
43
8.4 Additional Functions
43
8.5 Shutting Down
43
8.5.1 Frost Protection
44
8.6 System Shutdown
44
8.6.1 Frost Protection
44
9.1 Directly Via The Operating Panel
45
9.1.1 Appliance On/Off
45
9.1.2 Dhw Comfort
45
9.1.3 Resetting
45
9.1.4 Changing The Settings Of The Various Functions:
45
9.1.5 Maximum Ch Supply Temperature
45
9.1.6 Dhw Temperature
45
9.2 Settings Through The Service Code
46
9.3 Parameters
46
9.3.1 Enable/Disable Keep Hot Facility By Open Therm Room Thermostat
47
9.4 Setting Maximum Ch Power
48
9.5 Setting Pump Position
48
9.6 Weather-Dependent Control
48
9.7 Conversion To Different Gas Type
49
1.1.1 Converting The Gas Restriction
49
9.8 Gas-Air Ratio Control
50
9.9 Checking The Gas Air Ratio Control
51
9.9.1 Checking Flue Gas At Maximum Power
51
9.9.2 Checking Flue Gas At Minimum Power
52
9.9.3 Correction Gas Air Ratio On Minimum Power
53
10.1 Fault Codes
55
10.2 Other Faults
57
10.2.1 Burner Does Not Ignite
57
10.2.2 Burner Ignites Noisily
57
10.2.3 Burner Resonating
58
10.2.4 No Heating (Ch)
58
10.2.5 The Power Is Reduced
58
10.2.6 Ch Does Not Reach Temperature
58
10.2.7 No Hot Water (Dhw)
59
10.2.8 Hot Water Does Not Reach Temperature
59
10.2.9 Led On Ch Pump Is Flashing Alternately Red And Green
59
10.2.10 Led On Ch Pump Is Flashing Red
59
11.1 Disassembly
60
11.2 Assembly
61
11.3 Combustion
62
11.4 Ntc Resistances
62
11.5 Electrical Diagram
63
Discussie
Laat een opmerking achter of stel een vraag
Doe mee aan de discussie
Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.