Gebruik de reader hieronder om de De Dietrich DTG 330 CV Ketel handleiding te lezen. U kunt de handleidingen direct op de pagina doorbladeren en de functies van onze reader gebruiken om alle belangrijke informatie over de installatie, bediening en het onderhoud van deze De Dietrich CV Ketel te vinden.
Handleiding
Volledig schermFoutcodes
Hieronder vindt u de error codes voor de De Dietrich DTG 330.
Boiler sensor - The sensor circuit has been broken or short circuited.
The installation is stopped. Advise the installer.
Domestic hot water sensor - The sensor is cut.
The installation continues to operate but domestic hot water heating is no longer covered. Advise the installer.
Titanium anode - A short circuit has occurred on the titanium anode or connection reversed.
Production of domestic hot water is stopped. This may be reactivated for 24 hours by disconnecting and reconnecting the power supply to the boiler. Advise the installer.
Titanium anode - The titanium anode is on an open circuit or the tank is empty.
Production of domestic hot water is stopped. This may be reactivated for 24 hours by disconnecting and reconnecting the power supply to the boiler. Advise the installer.
Probleemoplossing
Praktische tips om de meest voorkomende problemen met De Dietrich DTG 330 op te lossen.
Oorzaak: The safety control box is malfunctioning or shutdown by the safety thermostat due to accidental overheating
Press the resetting button of the burner. Remove the safety thermostat hood and press the reset button with a screwdriver. Carry out the start-up operations again. Call your fitter.
Oorzaak: Safety thermostat has triggered, radiators need bleeding, primary circuit low on water, circuit breaker issue, heating pump not operating correctly, or 3 position switch in wrong position
Check that the safety thermostat has not triggered and reset if necessary. Bleed the radiators. Top up the primary circuit with water. Check the circuit breaker. Check that the heating pump is operating correctly. Check the position of the 3 position switch (TEST-STB/./% on . for B3, AUTO/!/TEST STB on AUTO for DIEMATIC-m3 and K3). Check the boiler thermostat settings.
Oorzaak: Presence of an override on a remote control
To cancel the overrides on all remote controls, press the AUTO key for 5 seconds.
Oorzaak: When connecting voltage, if the hot water tank temperature is below 25 ºC, the boiler carries out a domestic water exchanger purge cycle
Wait 1 minute.
Veelgestelde Vragen
De meest gestelde vragen over de De Dietrich DTG 330.
Hulp
Heb je vragen over de CV Ketel DTG 330 van De Dietrich? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.
Gerelateerde handleidingen
Hieronder vindt u handleidingen voor CV Ketel die vergelijkbaar zijn met DTG 330. Probeer ook alle De Dietrich CV Ketel handleidingen te bekijken
Discussie
Laat een opmerking achter of stel een vraag
Doe mee aan de discussie
Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.