Probleemoplossing

Praktische tips om de meest voorkomende problemen met Vaillant VIH S 500 op te lossen.

Water leaks from hot water pipes water

Oorzaak: Leaks in the piping between the boiler and the water outlet point

Oplossing

Close the cold water shut-off valve on the boiler and have a qualified technician eliminate the leak points

Boiler freezes during prolonged inactivity maintenance

Oorzaak: Boiler remains inactive in an unheated room for an extended period (e.g., winter holidays)

Oplossing

Completely drain the boiler if it will be inactive in an unheated location for a prolonged period

Reduced boiler capacity after startup performance

Oorzaak: First heating or prolonged shutdown period

Oplossing

Allow time for the boiler to reach full operating capacity. During the first heating cycle or after a prolonged shutdown, the full power of the boiler is not instantly available

Lime scale accumulation maintenance

Oorzaak: Hard water with high lime content

Oplossing

Perform periodic descaling of the boiler when operating in areas with hard water

Excessive heat loss from boiler installation

Oorzaak: Boiler not installed close to heat generator or hydraulic piping not insulated

Oplossing

Install the accumulation boiler close to the heat generator to avoid unnecessary heat loss. Insulate all hydraulic piping in accordance with heating system regulations

Overpressure in solar boiler water

Oorzaak: Safety valve or discharge tube blocked or closed

Oplossing

Do not close the safety valve or discharge tube to prevent excessive overpressure (exceeding 10 bar) from developing in the solar boiler

Water discharge from safety valve during heating water

Oorzaak: Normal operation - water volume expansion during heating

Oplossing

This is normal operation. Ensure the safety valve discharge tube terminates at a suitable drainage point that poses no danger to persons. Do not close the safety valve or discharge tube

Hulp

Heb je vragen over de Boiler VIH S 500 van Vaillant? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Boiler die vergelijkbaar zijn met VIH S 500. Probeer ook alle Vaillant Boiler handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in