1 About This Document
5
2 Safety Regulations
8
3 System Description
12
3.1 System Overview
12
3.2 Features
12
3.3 Technical Data
13
3.3.1 Electrical Data
13
3.3.2 Mechanical Data
14
3.3.3 Environmental Conditions
15
3.4 Standard And Options En 54
16
4 Installation
17
4.1 Power Supply – Mains Voltage Connection
17
4.2 Instruction
19
4.2.1 Connection Overview
20
4.3 Zone Modes
21
4.3.1 Standard
21
4.3.2 Mixed
22
4.3.3 Gb Continuity
23
4.3.4 Short = Alarm
24
4.4 Outputs
25
4.4.1 Main Board (Out1 / Out2)
25
4.4.2 Output Card (Outa / Outb)
25
4.4.3 Relay
27
4.4.4 Dialer Connection
28
4.5 Input
29
4.6 Accessories
30
4.6.1 Key Switch Set
30
4.6.2 Output Card
31
4.6.3 Evac Module (Nl)
33
4.6.4 Zone Indication Field
34
4.7 Initial Start-Up
35
4.7.1 Prepare The Panel
35
4.7.2 Pre Configuration
36
5 Function Overview
37
5.1 Operating Functions
37
5.2 Access Levels
37
5.3 Led Indication
38
5.4 Buttons
39
5.5 Display
40
5.6 Code Entry
40
6 Operation
41
6.1 General Fire Alarm Procedure
41
6.1.1 Procedure Without Alarm Verification
42
6.1.2 Alarm Verification Concept (Avc)
43
6.1.3 Procedure With Alarm Verification
44
6.2 Fault Procedure
46
6.3 Access Level 1
47
6.3.1 Actual Events
47
6.3.2 Login
48
6.3.3 Alarm Counter
48
6.4 Access Level 2
49
6.4.1 Manned / Unmanned
49
6.4.2 Silence / Resound
49
6.4.3 Led, Lcd And Buzzer Test
49
6.4.4 Display History Log
50
6.4.5 Logout
50
6.4.6 Set Date And Time
52
6.4.7 Enable / Disable Zone
53
6.4.8 Enable Test Mode
54
6.4.9 Enable / Disable Outputs
55
6.4.10 Panel Information
56
6.4.11 Service Information
56
7 Programming
57
7.1 Configure
57
7.1.1 Zone
57
7.1.2 Output
58
7.1.3 Input
59
7.1.4 Accessories
60
7.2 Global
61
7.2.1 Country Settings
61
7.2.2 Language
61
7.2.3 Change Password
61
7.2.4 User Interface
62
7.2.5 Zone Options
62
7.2.6 Output Options
62
7.2.7 Mains Power
62
7.2.8 Date & Time
63
7.2.9 Summer / Winter Time
63
7.2.10 Manned / Unmanned
63
7.2.11 Service Information
63
7.2.12 Buzzer
63
7.2.13 Calibrate Line
63
7.2.14 Delete History Log
64
7.3 Logout
64
7.4 Reset Alarm Counter
65
7.5 Customer Text
66
7.5.1 Button Function
66
7.5.2 Text Entry
67
8 Tool Function
68
8.1 Set Up Communication
68
8.1.1 Tool Installation
68
8.1.2 Tool Settings
69
8.2 Transfer History Log Data To Pc
70
8.3 Save Configuration File
71
8.4 Restore Configuration File
72
8.5 Download Firmware
73
9 Commissioning
75
10 Maintenance
76
10.1 Preparatory Work
76
10.2 Function Test
76
10.3 Device Test
77
10.4 Completion Work
77
11 Battery Capacity
78
11.1 Fc121-Za Calculation
78
11.2 Fc122-Za Calculation
79
11.3 Fc123-Za Calculation
80
11.4 Fc124-Za Calculation
81
12 Trouble Shooting
82
12.1 Led Indication
82
12.2 System
83
12.3 Accessories
83
12.4 Factory Reset
84
13 Components And Spare Parts
85
14 Disposal And Environmental Protection
86
Appendix A: Site Configuration, Factory Setting
87
Appendix B: Switch Mains To Ac 115 V
89
Appendix C: History Log
90
Discussie
Laat een opmerking achter of stel een vraag
Hallo, ik ben bezig met de installatie van een FC123-ZA en ik snap niet goed hoe ik de zones moet instellen. Wat is precies het verschil tussen de Standard modus en de Mixed modus? De handleiding is in het Engels en dat maakt het er niet makkelijker op.
Dat begrijp ik, die Engelse handleiding is inderdaad niet altijd even handig. In de Standard modus werkt elke zone op dezelfde manier met de gebruikelijke eindweerstand. Bij de Mixed modus kun je op dezelfde zone zowel rookmelders als handmelders combineren, wat in bepaalde gebouwen handig is. Kijk even goed naar hoofdstuk 4.3 in de technische handleiding, daar staat per modus ook een aansluitschema getekend wat het veel duidelijker maakt.
Doe mee aan de discussie
Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.