Foutcodes

Hieronder vindt u de error codes voor de Gree VIR18HP230V1AO.

C5

System Configuration C5 1) No jumper cap inserted on the control board. Malfunction 2) Incorrect or damaged jumper cap on control board.

E1

System High Pressure E1 1) Over charged with refrigerant. 2) Blocked or dirty outdoor coil .

E2

Indoor Anti-Freeze Protection E2 3 flashes 1) Low return airflow. and 2) Indoor fan speed is too low.

E4

Compressor High Discharge E4 7 flashes Please refer to the malfunction analysis (discharge Temperature Protection and temperature, overload) in service manual.

E5

Overcurrent Protection E5 5 flashes 1) Supply voltage is unstable. and 2) Supply voltage is too low and system load is too high.

E6

Communication Malfunction E6 Continuous 1) Communication cable is mis-wired between indoor On and outdoor units.

E8

High Temperature E8 6 flashes 1) Incorrect refrigerant charge level. Resistant Protection and 2) Refrigerant metering device malfunction.

F0

Refrigerant Leakage Protection F0 9 flashes 1) refrigerant leak(s). and 2) Indoor coil temperature sensor no calibrated.

F1

Indoor Ambient Temperature F1 1) Loose or bad connection between sensor and control board. Sensor Malfunction 2) Indoor ambient temperature sensor damaged.

F2

Indoor Coil Temperature F2 1) Loose or bad connection between sensor and control board. Sensor Malfunction 2) Indoor coil temperature sensor damaged.

F3

Outdoor Ambient Temperature F3 6 flashes 1) Loose or bad connection between sensor and control board. Sensor Malfunction and 2) Outdoor ambient temperature sensor damaged.

F4

Outdoor Coil Temperature F4 5 flashes 1) Loose or bad connection between sensor and control board. Sensor Malfunction and 2) Outdoor coil temperature sensor damaged.

F5

Outdoor Discharge Temperature F5 7 flashes 1) Loose or bad connection between sensor and control board. Sensor Malfunction and 2) Discharge temperature sensor damaged.

H3

Compressor Overload Protection H3 8 flashes 1) Wiring terminal OVC-COMP is loose. and 2) Refer to the malfunction analysis in Service Manual.

L1

High DC Bus Voltage Protection PH 13 flashes 1) Supply voltage on L1 and N is above 265Vac. and 2) Capacitor on control board malfunction.

P5

Compressor Phase Current P5 1) IPM module malfunction. Protection 2) Outdoor control board malfunction

P7

Module Temperature Sensor P7 Outdoor control board malfunction Malfunction

P8

Module Temperature Protection P8 1) Lack of thermal grease on IPM module. 2) Heat sink (radiator) not tightly mounted.

Hulp

Heb je vragen over de Airco VIR18HP230V1AO van Gree? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Airco die vergelijkbaar zijn met VIR18HP230V1AO. Probeer ook alle Gree Airco handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in