Volledig schermFoutcodes
Hieronder vindt u de error codes voor de Fujitsu Airstage AJYA90LALH.
Communication error between outdoor units
Check communication wiring between outdoor units
Outdoor unit network communication 1 error
Verify network communication connections
Outdoor unit network communication 2 error
Verify network communication connections
The number of indoor unit shortage
Check indoor unit connections and count
Auto address setting error
Retry auto address setting procedure
Signal amplifier auto address error
Check signal amplifier address setting
Indoor unit miscellaneous error
Check indoor unit for faults
Outdoor unit reverse/missing phase & wiring error
Check power supply phase and wiring connections
Outdoor unit EEPROM access error
Check outdoor unit PCB and memory
Outdoor unit inverters communication error
Check inverter communication connections
Outdoor unit EEPROM data corruption error
Check outdoor unit PCB memory integrity
Outdoor unit inverter error
Check outdoor unit inverter operation
Outdoor unit inverter PCB power short interruption
Check inverter PCB for power issues
Outdoor unit magnetic relay error
Check magnetic relay operation
Outdoor unit rush current limiting resister temp. rise error (protective operation)
Check rush current limiting resistor temperature
Outdoor unit transmission PCB parallel communication error
Check transmission PCB communication
Outdoor unit discharge temp. thermistor 1 error
Check discharge temperature thermistor 1
Outdoor unit discharge temp. thermistor 2 error
Check discharge temperature thermistor 2
Outdoor unit compressor temp. thermistor 1 error
Check compressor temperature thermistor 1
Outdoor unit compressor temp. thermistor 2 error
Check compressor temperature thermistor 2
Outdoor unit heat ex. liquid temp. thermistor error
Check heat exchanger liquid temperature thermistor
Outside air temp. thermistor error
Check outside air temperature thermistor
Outdoor unit suction gas temp. thermistor error
Check suction gas temperature thermistor
Outdoor unit heat sink temp. thermistor error
Check heat sink temperature thermistor
Outdoor unit sub-cool heat ex. gas inlet temp. thermistor error
Check sub-cool heat exchanger gas inlet thermistor
Outdoor unit sub-cool heat ex. gas outlet temp. thermistor error
Check sub-cool heat exchanger gas outlet thermistor
Outdoor unit liquid pipe temp. thermistor 1 error
Check liquid pipe temperature thermistor 1
Outdoor unit liquid pipe temp. thermistor 2 error
Check liquid pipe temperature thermistor 2
Outdoor unit current sensor 1 error (permanent stop)
Check current sensor 1 operation
Outdoor unit discharge pressure sensor error
Check discharge pressure sensor
Outdoor unit suction pressure sensor error
Check suction pressure sensor
Outdoor unit high pressure switch 1 error
Check high pressure switch 1
Outdoor unit high pressure switch 2 error
Check high pressure switch 2
Outdoor unit compressor 2 error
Check outdoor unit compressor operation
Outdoor unit compressor 2 current value error
Verify compressor current values
Outdoor unit inverter compressor start up error
Check inverter and compressor startup sequence
Outdoor unit trip detection
Verify outdoor unit protection systems
Outdoor unit compressor motor loss of synchronization error
Check compressor motor synchronization
Outdoor unit fan motor 1 lock error
Check outdoor unit fan motor for blockage
Outdoor unit fan motor 1 undervoltage error
Verify power supply voltage to fan motor
Outdoor unit fan motor 1 temperature error (protective action)
Check fan motor temperature and cooling
Outdoor slave unit error
Check outdoor slave unit connection and operation
Outdoor unit discharge temperature 1 error (permanent stop)
Check discharge temperature sensor and system
Outdoor unit discharge temperature 2 error (permanent stop)
Check discharge temperature sensor and system
Outdoor unit compressor 1 temperature error
Check compressor 1 temperature sensor
Outdoor unit compressor 2 temperature error
Check compressor 2 temperature sensor
Outdoor unit high pressure error
Check refrigerant pressure and system
Outdoor unit high pressure protective action 1
Monitor high pressure protective operation
Outdoor unit high pressure protective action 2
Monitor high pressure protective operation
Outdoor unit low pressure error
Check refrigerant pressure and system
Outdoor unit heat sink temperature error
Check heat sink temperature sensor
Probleemoplossing
Praktische tips om de meest voorkomende problemen met Fujitsu Airstage AJYA90LALH op te lossen.
Oorzaak: Water drainage path is blocked
Check drainage hose and clear any blockage by pouring water through it
Oorzaak: Low or high refrigerant pressure
Check high and low pressure values with pressure gauge. Normal cooling pressure approximately 0.8 MPa, heating pressure approximately 3.0 MPa
Oorzaak: Indoor or outdoor unit fans not running
Check visually that indoor and outdoor unit fans are operating
Oorzaak: Compressor not starting after indoor unit activation
Check operating sound to confirm compressor operation after indoor unit starts
Oorzaak: Temperature difference between inlet and outlet incorrect
Measure inlet and outlet temperatures. Normal temperature difference should be approximately 10 degrees
Oorzaak: Error not displayed or no error segment LED indicator
Check 7 segment LED indicator for error code display
Oorzaak: Operating mode not set correctly
Verify system is in correct mode: CL (Cooling), Ht (Heating), oF (Oil recovery), dF (Defrosting), PC (Peak cut), Ln (Low noise), Sn (Snowfall mode)
Veelgestelde Vragen
De meest gestelde vragen over de Fujitsu Airstage AJYA90LALH.
Hulp
Heb je vragen over de Airco Airstage AJYA90LALH van Fujitsu? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.
Gerelateerde handleidingen
Hieronder vindt u handleidingen voor Airco die vergelijkbaar zijn met Airstage AJYA90LALH. Probeer ook alle Fujitsu Airco handleidingen te bekijken
Discussie
Laat een opmerking achter of stel een vraag
Doe mee aan de discussie
Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.