Foutcodes

Hieronder vindt u de error codes voor de Fujitsu Airstage AJYA90LALH.

E113.1 communication
KRITIEK

Communication error between outdoor units

Oplossing

Check communication wiring between outdoor units

E114.1 communication
KRITIEK

Outdoor unit network communication 1 error

Oplossing

Verify network communication connections

E114.2 communication
KRITIEK

Outdoor unit network communication 2 error

Oplossing

Verify network communication connections

E114.5 communication
KRITIEK

The number of indoor unit shortage

Oplossing

Check indoor unit connections and count

E128.1 other
WAARSCHUWING

Auto address setting error

Oplossing

Retry auto address setting procedure

E128.4 communication
WAARSCHUWING

Signal amplifier auto address error

Oplossing

Check signal amplifier address setting

E15U.1 other
WAARSCHUWING

Indoor unit miscellaneous error

Oplossing

Check indoor unit for faults

E161.5 power
KRITIEK

Outdoor unit reverse/missing phase & wiring error

Oplossing

Check power supply phase and wiring connections

E162.3 other
KRITIEK

Outdoor unit EEPROM access error

Oplossing

Check outdoor unit PCB and memory

E162.6 communication
KRITIEK

Outdoor unit inverters communication error

Oplossing

Check inverter communication connections

E162.8 other
KRITIEK

Outdoor unit EEPROM data corruption error

Oplossing

Check outdoor unit PCB memory integrity

E163.1 power
KRITIEK

Outdoor unit inverter error

Oplossing

Check outdoor unit inverter operation

E167.2 power
KRITIEK

Outdoor unit inverter PCB power short interruption

Oplossing

Check inverter PCB for power issues

E168.1 power
WAARSCHUWING

Outdoor unit magnetic relay error

Oplossing

Check magnetic relay operation

E168.2 temperature
WAARSCHUWING

Outdoor unit rush current limiting resister temp. rise error (protective operation)

Oplossing

Check rush current limiting resistor temperature

E169.1 communication
KRITIEK

Outdoor unit transmission PCB parallel communication error

Oplossing

Check transmission PCB communication

E171.1 sensor
WAARSCHUWING

Outdoor unit discharge temp. thermistor 1 error

Oplossing

Check discharge temperature thermistor 1

E171.2 sensor
WAARSCHUWING

Outdoor unit discharge temp. thermistor 2 error

Oplossing

Check discharge temperature thermistor 2

E172.1 sensor
WAARSCHUWING

Outdoor unit compressor temp. thermistor 1 error

Oplossing

Check compressor temperature thermistor 1

E172.2 sensor
WAARSCHUWING

Outdoor unit compressor temp. thermistor 2 error

Oplossing

Check compressor temperature thermistor 2

E173.3 sensor
WAARSCHUWING

Outdoor unit heat ex. liquid temp. thermistor error

Oplossing

Check heat exchanger liquid temperature thermistor

E174.1 sensor
WAARSCHUWING

Outside air temp. thermistor error

Oplossing

Check outside air temperature thermistor

E175.1 sensor
WAARSCHUWING

Outdoor unit suction gas temp. thermistor error

Oplossing

Check suction gas temperature thermistor

E177.1 sensor
WAARSCHUWING

Outdoor unit heat sink temp. thermistor error

Oplossing

Check heat sink temperature thermistor

E182.1 sensor
WAARSCHUWING

Outdoor unit sub-cool heat ex. gas inlet temp. thermistor error

Oplossing

Check sub-cool heat exchanger gas inlet thermistor

E182.2 sensor
WAARSCHUWING

Outdoor unit sub-cool heat ex. gas outlet temp. thermistor error

Oplossing

Check sub-cool heat exchanger gas outlet thermistor

E183.1 sensor
WAARSCHUWING

Outdoor unit liquid pipe temp. thermistor 1 error

Oplossing

Check liquid pipe temperature thermistor 1

E183.2 sensor
WAARSCHUWING

Outdoor unit liquid pipe temp. thermistor 2 error

Oplossing

Check liquid pipe temperature thermistor 2

E184.1 sensor
KRITIEK

Outdoor unit current sensor 1 error (permanent stop)

Oplossing

Check current sensor 1 operation

E186.1 sensor
WAARSCHUWING

Outdoor unit discharge pressure sensor error

Oplossing

Check discharge pressure sensor

E186.3 sensor
WAARSCHUWING

Outdoor unit suction pressure sensor error

Oplossing

Check suction pressure sensor

E186.4 sensor
WAARSCHUWING

Outdoor unit high pressure switch 1 error

Oplossing

Check high pressure switch 1

E186.5 sensor
WAARSCHUWING

Outdoor unit high pressure switch 2 error

Oplossing

Check high pressure switch 2

E913.1 compressor
KRITIEK

Outdoor unit compressor 2 error

Oplossing

Check outdoor unit compressor operation

E913.2 compressor
KRITIEK

Outdoor unit compressor 2 current value error

Oplossing

Verify compressor current values

E913.3 compressor
KRITIEK

Outdoor unit inverter compressor start up error

Oplossing

Check inverter and compressor startup sequence

E914.1 power
KRITIEK

Outdoor unit trip detection

Oplossing

Verify outdoor unit protection systems

E915.5 motor
KRITIEK

Outdoor unit compressor motor loss of synchronization error

Oplossing

Check compressor motor synchronization

E917.1 fan
WAARSCHUWING

Outdoor unit fan motor 1 lock error

Oplossing

Check outdoor unit fan motor for blockage

E917.4 power
WAARSCHUWING

Outdoor unit fan motor 1 undervoltage error

Oplossing

Verify power supply voltage to fan motor

E917.5 temperature
WAARSCHUWING

Outdoor unit fan motor 1 temperature error (protective action)

Oplossing

Check fan motor temperature and cooling

E91U.2 communication
KRITIEK

Outdoor slave unit error

Oplossing

Check outdoor slave unit connection and operation

EA1.1 temperature
KRITIEK

Outdoor unit discharge temperature 1 error (permanent stop)

Oplossing

Check discharge temperature sensor and system

EA2.1 temperature
KRITIEK

Outdoor unit discharge temperature 2 error (permanent stop)

Oplossing

Check discharge temperature sensor and system

EA3.1 temperature
WAARSCHUWING

Outdoor unit compressor 1 temperature error

Oplossing

Check compressor 1 temperature sensor

EA3.2 temperature
WAARSCHUWING

Outdoor unit compressor 2 temperature error

Oplossing

Check compressor 2 temperature sensor

EA4.1 other
KRITIEK

Outdoor unit high pressure error

Oplossing

Check refrigerant pressure and system

EA4.2 other
WAARSCHUWING

Outdoor unit high pressure protective action 1

Oplossing

Monitor high pressure protective operation

EA4.3 other
WAARSCHUWING

Outdoor unit high pressure protective action 2

Oplossing

Monitor high pressure protective operation

EA5.1 other
KRITIEK

Outdoor unit low pressure error

Oplossing

Check refrigerant pressure and system

EAC.4 temperature
WAARSCHUWING

Outdoor unit heat sink temperature error

Oplossing

Check heat sink temperature sensor

Probleemoplossing

Praktische tips om de meest voorkomende problemen met Fujitsu Airstage AJYA90LALH op te lossen.

Drainage issue water

Oorzaak: Water drainage path is blocked

Oplossing

Check drainage hose and clear any blockage by pouring water through it

Low or no cooling/heating performance performance

Oorzaak: Low or high refrigerant pressure

Oplossing

Check high and low pressure values with pressure gauge. Normal cooling pressure approximately 0.8 MPa, heating pressure approximately 3.0 MPa

System not operating fan

Oorzaak: Indoor or outdoor unit fans not running

Oplossing

Check visually that indoor and outdoor unit fans are operating

Delayed operation compressor

Oorzaak: Compressor not starting after indoor unit activation

Oplossing

Check operating sound to confirm compressor operation after indoor unit starts

Incorrect temperature control temperature

Oorzaak: Temperature difference between inlet and outlet incorrect

Oplossing

Measure inlet and outlet temperatures. Normal temperature difference should be approximately 10 degrees

LED indicator shows no error code display

Oorzaak: Error not displayed or no error segment LED indicator

Oplossing

Check 7 segment LED indicator for error code display

System not operating in expected mode performance

Oorzaak: Operating mode not set correctly

Oplossing

Verify system is in correct mode: CL (Cooling), Ht (Heating), oF (Oil recovery), dF (Defrosting), PC (Peak cut), Ln (Low noise), Sn (Snowfall mode)

Veelgestelde Vragen

De meest gestelde vragen over de Fujitsu Airstage AJYA90LALH.

Controleer de werking via de 7-segment LED-indicator. Normale bedrijfsmodi zijn: CL voor koeling, Ht voor verwarming, oF voor olieterugwinning, dF voor ontdooiing, PC voor pieklast, Ln voor stillewerking, en Sn voor sneeuwmodus.

Controleer de 7-segment LED-indicator. Het kan betekenen dat er geen fout is gedetecteerd, of dat de indicator niet correct werkt.

In koelmodus bedraagt de normale lage druk ongeveer 0,8 MPa. In verwarmingsmodus bedraagt de normale hoge druk ongeveer 3,0 MPa. Meet deze waarden met een drukmeter.

Controleer of water correct uit het afvoerslangje komt. Als het drainageslangje verstopt is, spoel het door water erin te gieten totdat het correct afvloeit.

Het normale temperatuurverschil bedraagt ongeveer 10 graden tussen de inlaat- en uitlaattemperaturen. Meet beide temperaturen om dit te verifiëren.

Dit is normaal gedrag. Controleer het bedrijfsgeluid om te bevestigen dat de compressor correct start na het activeren van de binneneenheid.

Controleer visueel of beide ventilatoren draaien wanneer het systeem actief is. Beide moeten in bedrijf zijn voor correct functioneren.

Hulp

Heb je vragen over de Airco Airstage AJYA90LALH van Fujitsu? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Airco die vergelijkbaar zijn met Airstage AJYA90LALH. Probeer ook alle Fujitsu Airco handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in