Foutcodes

Hieronder vindt u de error codes voor de Fujitsu Airstage AJYA72LALH.

E113.1 communication
KRITIEK

Communication error between outdoor units

Oplossing

Check communication cables and connections between units

E114.1 communication
WAARSCHUWING

Outdoor unit network communication 1 error

Oplossing

Check network communication cables and settings

E114.2 communication
WAARSCHUWING

Outdoor unit network communication 2 error

Oplossing

Check network communication cables and settings

E114.5 communication
WAARSCHUWING

The number of indoor unit shortage

Oplossing

Check indoor unit connections and quantity

E128.1 other
WAARSCHUWING

Auto address setting error

Oplossing

Retry auto address setting procedure

E128.4 other
WAARSCHUWING

Signal amplifier auto address error

Oplossing

Check signal amplifier and retry address setting

E15U.1 other
WAARSCHUWING

Indoor unit miscellaneous error

Oplossing

Check indoor unit for general errors

E161.5 power
KRITIEK

Outdoor unit reverse/missing phase & wiring error

Oplossing

Check electrical phase and wiring connections

E162.3 other
KRITIEK

Outdoor unit EEPROM access error

Oplossing

Check EEPROM and electronic components

E162.6 communication
KRITIEK

Outdoor unit inverters communication error

Oplossing

Check inverter communication connections

E162.8 other
KRITIEK

Outdoor unit EEPROM data corruption error

Oplossing

Check and replace EEPROM if necessary

E163.1 power
KRITIEK

Outdoor unit inverter error

Oplossing

Check inverter operation and power supply

E167.2 power
KRITIEK

Outdoor unit inverter PCB power short interruption

Oplossing

Check inverter PCB for shorts and power supply

E168.1 power
WAARSCHUWING

Outdoor unit magnetic relay error

Oplossing

Check magnetic relay operation

E168.2 temperature
WAARSCHUWING

Outdoor unit rush current limiting resister temp. rise error (protective operation)

Oplossing

Check rush current limiting resistor and cooling

E169.1 communication
WAARSCHUWING

Outdoor unit transmission PCB parallel communication error

Oplossing

Check PCB communication connections

E171.1 sensor
WAARSCHUWING

Outdoor unit discharge temp. thermistor 1 error

Oplossing

Check and replace discharge temperature thermistor 1

E171.2 sensor
WAARSCHUWING

Outdoor unit discharge temp. thermistor 2 error

Oplossing

Check and replace discharge temperature thermistor 2

E172.1 sensor
WAARSCHUWING

Outdoor unit compressor temp. thermistor 1 error

Oplossing

Check and replace compressor temperature thermistor 1

E172.2 sensor
WAARSCHUWING

Outdoor unit compressor temp. thermistor 2 error

Oplossing

Check and replace compressor temperature thermistor 2

E173.3 sensor
WAARSCHUWING

Outdoor unit heat ex. liquid temp. thermistor error

Oplossing

Check and replace heat exchanger liquid temperature thermistor

E174.1 sensor
WAARSCHUWING

Outside air temp. thermistor error

Oplossing

Check and replace outside air temperature thermistor

E175.1 sensor
WAARSCHUWING

Outdoor unit suction gas temp. thermistor error

Oplossing

Check and replace suction gas temperature thermistor

E177.1 sensor
WAARSCHUWING

Outdoor unit heat sink temp. thermistor error

Oplossing

Check and replace heat sink temperature thermistor

E182.1 sensor
WAARSCHUWING

Outdoor unit sub-cool heat ex. gas inlet temp. thermistor error

Oplossing

Check and replace gas inlet temperature thermistor

E182.2 sensor
WAARSCHUWING

Outdoor unit sub-cool heat ex. gas outlet temp. thermistor error

Oplossing

Check and replace gas outlet temperature thermistor

E183.1 sensor
WAARSCHUWING

Outdoor unit liquid pipe temp. thermistor 1 error

Oplossing

Check and replace liquid pipe temperature thermistor 1

E183.2 sensor
WAARSCHUWING

Outdoor unit liquid pipe temp. thermistor 2 error

Oplossing

Check and replace liquid pipe temperature thermistor 2

E184.1 sensor
KRITIEK

Outdoor unit current sensor 1 error (permanent stop)

Oplossing

Check and replace current sensor 1

E186.1 sensor
WAARSCHUWING

Outdoor unit discharge pressure sensor error

Oplossing

Check and replace discharge pressure sensor

E186.3 sensor
WAARSCHUWING

Outdoor unit suction pressure sensor error

Oplossing

Check and replace suction pressure sensor

E186.4 sensor
WAARSCHUWING

Outdoor unit high pressure switch 1 error

Oplossing

Check and replace high pressure switch 1

E186.5 sensor
WAARSCHUWING

Outdoor unit high pressure switch 2 error

Oplossing

Check and replace high pressure switch 2

E913.1 compressor
KRITIEK

Outdoor unit compressor 2 error

Oplossing

Check outdoor unit compressor 2 operation

E913.2 compressor
KRITIEK

Outdoor unit compressor 2 current value error

Oplossing

Check compressor 2 current values

E913.3 compressor
KRITIEK

Outdoor unit inverter compressor start up error

Oplossing

Check inverter and compressor startup sequence

E914.1 power
KRITIEK

Outdoor unit trip detection

Oplossing

Check outdoor unit for trip conditions

E915.5 motor
KRITIEK

Outdoor unit compressor motor loss of synchronization error

Oplossing

Check motor synchronization and electrical connections

E917.1 fan
WAARSCHUWING

Outdoor unit fan motor 1 lock error

Oplossing

Check fan motor 1 for obstructions or mechanical damage

E917.4 fan
WAARSCHUWING

Outdoor unit fan motor 1 undervoltage error

Oplossing

Check power supply voltage to fan motor 1

E917.5 temperature
WAARSCHUWING

Outdoor unit fan motor 1 temperature error (protective action)

Oplossing

Allow unit to cool, check fan motor temperature sensor

E91U.2 communication
KRITIEK

Outdoor slave unit error

Oplossing

Check outdoor slave unit communication and operation

E9A1.1 temperature
KRITIEK

Outdoor unit discharge temperature 1 error (permanent stop)

Oplossing

Check discharge temperature thermistor and refrigerant system

E9A2.1 temperature
KRITIEK

Outdoor unit discharge temperature 2 error (permanent stop)

Oplossing

Check discharge temperature thermistor and refrigerant system

E9A3.1 temperature
WAARSCHUWING

Outdoor unit compressor 1 temperature error

Oplossing

Check compressor 1 temperature sensor

E9A3.2 temperature
WAARSCHUWING

Outdoor unit compressor 2 temperature error

Oplossing

Check compressor 2 temperature sensor

E9A4.1 other
KRITIEK

Outdoor unit high pressure error

Oplossing

Check refrigerant charge and high pressure system

E9A4.2 other
WAARSCHUWING

Outdoor unit high pressure protective action 1

Oplossing

Check refrigerant charge and system pressure

E9A4.3 other
WAARSCHUWING

Outdoor unit high pressure protective action 2

Oplossing

Check refrigerant charge and system pressure

E9A5.1 other
KRITIEK

Outdoor unit low pressure error

Oplossing

Check refrigerant charge and low pressure system

E9AC.4 temperature
WAARSCHUWING

Outdoor unit heat sink temperature error

Oplossing

Check heat sink temperature sensor

Probleemoplossing

Praktische tips om de meest voorkomende problemen met Fujitsu Airstage AJYA72LALH op te lossen.

Drainwater loopt niet goed af water

Oorzaak: Afvoeropening of slang is verstopt

Oplossing

Controleer de afvoeropening en slang op verstoppingen en reinig deze indien nodig

Binnen- en buitenunit ventilators draaien niet performance

Oorzaak: Voeding is uitgeschakeld of ventilatormotor is defect

Oplossing

Controleer of de voeding ingeschakeld is en controleer de ventilatormotor visueel op beschadigingen

Compressor start niet op nadat binnenunit actief is performance

Oorzaak: Vertraging in normale werking of compressor defect

Oplossing

Luister naar bedrijfsgeluiden van de compressor en wacht op normale opstartsequentie

Temperatuurverschil tussen inlaat en uitlaat is abnormaal temperature

Oorzaak: Koelmiddelsysteem heeft onvoldoende capaciteit of thermistor is defect

Oplossing

Meet inlaat- en uitlaattemperatuur en controleer of het verschil ongeveer 10 graden bedraagt

Geen LED-code weergave op paneel display

Oorzaak: LED-indicator is beschadigd of elektronisch probleem

Oplossing

Controleer het 7-segment LED-indicatorpaneel op schade of vervangingsbehoefte

Hoge druk in koelsysteem temperature

Oorzaak: Overbelading koelmiddel, vervuilde condensor of ondoelmatige verkoeling

Oplossing

Controleer koelmiddelladingen en condensorvervuiling, zorg voor goede ventilatie rond buitenunit

Lage druk in koelsysteem temperature

Oorzaak: Koelmiddel lek, onderdelen verstopt of thermostaat instelling onjuist

Oplossing

Controleer op koelmiddellekken en desinfecteer het systeem, verifieer thermostaat instelling

Veelgestelde Vragen

De meest gestelde vragen over de Fujitsu Airstage AJYA72LALH.

CL = Koeling, Ht = Verwarming, dF = Ontdooiingsbewerking, oF = Olierecuperatiebewerking, PC = Piekuitsnijding, Ln = Stille bedrijfsmode, Sn = Sneeuwvalmodusinstelling

Gebruik een drukmanometer. Voor koeling moet de lage druk ongeveer 0,8 MPa zijn. Voor verwarming moet de hoge druk ongeveer 3,0 MPa zijn.

Raadpleeg de tabel met foutcodes in de handleiding. Voer de aanbevolen oplossing uit. Voor kritieke fouten (permanent stop) dient u contact op te nemen met de servicetechnicus.

De 7-segment LED-indicator geeft de bedrijfsstatus aan door op te lichten en te knipperen. Controleer de status aan de hand van de tabel met normale bedrijfscodes en foutcodes in de handleiding.

Controleer of water alleen uit de afvoeropening komt. Controleer of de drain kat open is. Giet water in de drain om verstoppingen te verhelpen.

Foutenmeldingen kunnen afkomstig zijn van thermistors voor uitlaattemperatuur, compressortemperatuur, warmtewisselaar-temperatuur, buitenluchttemperatuur, zuiggas, warmteafvoer, onderkoelings-vervormde gastemperatuur en vloeistofpijptemperatuur.

Giet water in de drain en controleer visueel of het water alleen uit de afvoeropening stroomt. Zorg ervoor dat de drain kat open staat.

Normale bedrijfscondities voor koeling zijn gespecificeerd in het etiket op het apparaat met droge bol- en natte boltemperatuurwaarden onder standaard koelomstandigheden.

Hulp

Heb je vragen over de Airco Airstage AJYA72LALH van Fujitsu? Stel ze direct aan onze expert! Je krijgt informatie, praktische tips en oplossingen op maat in slechts enkele seconden.

Hieronder vindt u handleidingen voor Airco die vergelijkbaar zijn met Airstage AJYA72LALH. Probeer ook alle Fujitsu Airco handleidingen te bekijken

Discussie

Laat een opmerking achter of stel een vraag

Doe mee aan de discussie

Stel een vraag over de handleiding of voeg een nuttig antwoord toe voor andere gebruikers.

Voer hier uw bericht in
Voer uw naam in
Voer uw e-mailadres in